Matrix Appliances MHG200SS Instrukcja Obsługi Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 6
Gas Supply Requirements
IMPORTANT: THIS APPLIANCE SHOULD BE FITTED BY A GAS SAFE REGISTERED FITTER OR OTHER SUITABLY
QUALIFIED PERSON.
• ThisinstallationmustcomplywiththeGasSafety(installationanduse)Regulations1984.
• ThisapplianceiscategoryII2H3+andisdesignedforuseintheUKandIreland.Theinstallationmustcomplywith
the Gas Safety (installation and use) Regulations 1984.
• TheCDAGroupLtdisnotlegallyabletoprovideanyassistanceintheinstallationofgasappliancesexcepttoGas
Safe registered installers. Any Gas Safe registered fitter requiring help must provide their name, address and
registration number. Information supplied will be validated before help is provided.
• Intheeventthatthisapplianceisnotinstalledinaccordancewiththeaboverequirements,theappliancemaybe
• Thisapplianceshouldbeinstalledusing15mmcopperpipeconnectedviaashut-offvalveinanadjacentunit.The
shut-off valve needs to be accessible in an emergency or for service purposes.
• Thisappliancemustnotbeconnectedtoacombustiongasrecoveryscavengingsystem
• Theconnectiontothegassupplymustcomplywithallcurrentregulationsinforce.
• WearenotlegallyabletoofferadviceontheinstallationofgasappliancestononGasSaferegisteredpersonnel.
Ventilation
All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in
addition to a window (see below).
This unit must not be used in a room which is less than 5m
3
. The following table details the requirements based on the
kitchen volume (L x W x H) in m
3
.
The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in the same
room, consult the relevant British Standard (BS5440) or GAS SAFE document.
Room Volume (m
3
)
5
6 to 10
6 to 11
11 or more
Air Vent Required (cm
3
)
100
50
No permanent vent required if a door opens to the outside
None required
6
Przeglądanie stron 6
1 2 3 4 5 6 7 8 9 10 11 12

Komentarze do niniejszej Instrukcji

Brak uwag