Natural Gas to LPG Conversion
This hob can be converted from natural gas to propane operation at a nominal
inlet pressure of 37mbar, or butane operation at a nominal inlet pressure of
28/30mbar. This conversion must only be carried out by a competent person
(i.e. a Gas Safe registered fitter).
Instructions to fit replacement injectors:
1. Disconnect the appliance from the gas and electrical supplies.
2. Remove burner components and pan supports.
3. Remove the injectors and replace with the corresponding injector as shown
in the table below.
Setting up minimum flow rates:
1. Remove the control knobs.
2. Turn on the LP gas supply, light the burners and turn the controls to the
minimum position, as indicated by the small flame.
3. Insert a 2.5mm screwdriver into the hole at the top of the tap and turn the
adjustment screw fully clockwise as shown in figure 6.
4. Turn the controls to maximum position then quickly to the minimum
position - make sure the flame does not extinguish.
5. Replace the knobs.
LPG to Natural Gas Conversion
This hob can be converted from propane operation at a nominal inlet pressure of
37mbar or butane operation at a nominal inlet pressure of 28/30mbar to natural
gas at 20mbar. This conversion must only be carried out by a competent person
(i.e. a Gas Safe registered fitter).
Required:
• 7mmAFnutspinner
• Replacementinjectors
• NGidentityplate
Required:
• 7mmAFnutspinner
• Replacementinjectors
• LPGidentityplate
Fig.4
7
Burner LPG Injector Natural Gas Injector
Rapid 86 115
Semi-Rapid 67 97
Auxiliary 49 72
Triple ring / wok 100 135